HVAC building automation

HVAC & Building Automation

Purpose-built HVAC drives with BACnet/Modbus native communication, fire mode override, and automatic energy optimization for air handling units, chilled water pumps, cooling towers, and heat pump compressors.

  • BACnet MS/TP and Modbus RTU standard
  • Fire mode bypass per EN 12101-3
  • Automatic Energy Optimization (AEO)
  • Sleep mode for intermittent loads
Water treatment facility

Water & Wastewater

Multi-pump cascade control with dry-run protection, anti-cavitation monitoring, and pipe-fill mode for municipal water supply, sewage lift stations, and industrial effluent treatment systems.

  • Multi-pump cascade (up to 8 pumps)
  • Dry-run and minimum flow protection
  • Sensorless flow estimation
  • IP66/NEMA 4X enclosure options
Oil and gas facility

Oil & Gas

ATEX Zone 2 and IECEx certified drives for hazardous area installations — artificial lift, gas compression, pipeline boosting, and offshore platform utilities with SIL 2 rated safety functions.

  • ATEX Zone 2 / IECEx certification
  • SIL 2 functional safety (STO/SS1)
  • 690V supply voltage support
  • Extended temperature range -25°C to +55°C
Mining operation

Mining & Minerals

High-performance drives for conveyors, crushers, ball mills, and hoisting applications — with regenerative braking, flying start, and overload handling up to 150% for 60 seconds.

  • 150% overload for 60 seconds
  • Flying start into rotating loads
  • Active front end regenerative braking
  • Vibration-resistant design (IEC 60068-2-6)
Food processing facility

Food & Beverage

Washdown-rated drives for mixers, fillers, conveyors, and packaging machines — with conformal-coated PCBs for humidity resistance and dedicated recipe management for batch process control.

  • IP66/NEMA 4X washdown rated
  • Conformal-coated PCBs (3C3 environment)
  • STO for machine guarding
  • Recipe management via fieldbus
Data center cooling

Data Centers

Ultra-efficient drives for precision cooling systems — CRAH units, chilled water pumps, and cooling tower fans — achieving PUE improvements of 0.05-0.15 through continuous real-time airflow optimization.

  • Redundant control with automatic switchover
  • Ultra-low standby power (< 5W)
  • SNMP monitoring integration
  • EMC Class C1 compliance (IEC 61800-3)